ALL parts listed are in stock and ready for same day dispatch! Shop Now!

Free shipping over $100!

Australian Owned and Operated for 20+ years.

My Oven Spares  |  SKU: PTR15/1000

AVG 1000kPa 15mm 1/2" PTR Pressure Temperature Relief Valve PTR15/1000

$47.99
Tax included Shipping calculated at checkout.
Minimum Cart Quantity Discount Wholesale Price
Minimum Cart Amount Cart Discount


In Stock

In Stock

💧 AVG 1000kPa 15mm (½″) PRESSURE & TEMPERATURE RELIEF VALVE – PTR15/1000

Protect your hot water system from dangerous pressure and temperature build-up with this Genuine AVG 15mm (½″) Pressure & Temperature Relief Valve (PTR15/1000) ⚙️🔥
Manufactured by Australian Valve Group (AVG), this valve ensures safe, automatic discharge when pressure or temperature exceed safe operating limits — keeping your system efficient, reliable, and compliant with Australian Standards 🇦🇺


⚙️ Product Overview

The AVG PTR15/1000 is a high-quality brass combination valve that performs both pressure and temperature relief functions.
It’s designed for mains-pressure storage water heaters and automatically releases water when the internal tank temperature or pressure exceeds preset safety levels.

Essential for electric, gas, and solar hot water systems, this valve provides vital protection and peace of mind 💦


Key Features & Benefits

  • 🔹 Model: PTR15/1000

  • 🔹 Brand: AVG (Australian Valve Group)

  • 🔹 Connection Size: 15mm (½″ BSP male inlet × 15mm female outlet).

  • 🔹 Pressure Rating: 1000 kPa (kilopascals).

  • 🔹 Temperature Rating: 99°C.

  • 🔹 Type: Combination Pressure & Temperature Relief Valve.

  • 🔹 Material: Solid brass body with stainless-steel spring and lever.

  • 🔹 Function: Prevents excessive pressure and temperature buildup in hot water systems.

  • 🔹 Flow Rate: Meets AS1357.1 and WaterMark certification standards.

  • 🔹 Lever Type: Manual easing lever for quick testing and maintenance.

  • 🔹 Application: Suitable for domestic and commercial hot water systems up to 315L capacity.


🧾 Technical Specifications

Specification Detail
Model PTR15/1000
Brand AVG
Inlet Size 15mm (½″ BSP male)
Outlet Size 15mm female BSP
Pressure Rating 1000 kPa
Temperature Rating 99°C
Body Material Brass
Spring Material Stainless Steel
Certification WaterMark AS1357.1
Application Hot Water Systems

🧩 Applications

✅ Electric storage water heaters
✅ Gas hot water systems
✅ Solar hot water systems
✅ Commercial water storage units

💡 Tip: A PTR valve is a legal requirement on all storage hot water systems in Australia — it prevents tank rupture and ensures user safety.


🧑🔧 Installation Tips

⚠️ Must be installed by a licensed plumber in accordance with AS/NZS 3500 and AS1357.1.

1️⃣ Isolate the water and power supply.
2️⃣ Remove the existing PTR valve if fitted.
3️⃣ Apply thread seal tape to the male inlet.
4️⃣ Fit the new AVG PTR15/1000 securely into the heater’s relief port.
5️⃣ Attach discharge pipe pointing downward to a safe drain.
6️⃣ Turn on the supply and test the valve using the easing lever ✅

📸 Pro Tip: Operate the lever every 6 months to prevent scale buildup and ensure proper function.


💬 Common Signs You Need a New PTR Valve

💧 Constant dripping or leaking from discharge pipe
⚙️ Valve not releasing during test
🔥 Water temperature too high
🚫 Corroded or seized lever

Replacing your valve restores safe pressure control and prevents costly damage to your hot water tank.


🌟 Why Choose AVG?

✅ Australian-made & WaterMark certified 🇦🇺
✅ Trusted by plumbers nationwide
✅ Brass and stainless steel construction for longevity
✅ Compact, easy-to-install design
✅ Fully compliant with Australian Standards

AVG valves are reliable, durable, and designed for Australian water conditions, ensuring consistent protection and peace of mind for years to come 💪


📦 What’s Included

  • 1 × AVG PTR15/1000 Pressure & Temperature Relief Valve (1000kPa – 15mm / ½″)

  • Factory-sealed WaterMark certified packaging


🔍 SEO Keywords / Tags

AVG PTR15/1000, 15mm pressure temperature relief valve, ½ inch PTR valve, 1000kPa hot water valve, hot water system safety valve, AVG brass valve, WaterMark AS1357.1, Australian Valve Group PTR, HWS relief valve, AVG hot water parts Australia.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

My Oven Spares

AVG 1000kPa 15mm 1/2" PTR Pressure Temperature Relief Valve PTR15/1000

$47.99

💧 AVG 1000kPa 15mm (½″) PRESSURE & TEMPERATURE RELIEF VALVE – PTR15/1000

Protect your hot water system from dangerous pressure and temperature build-up with this Genuine AVG 15mm (½″) Pressure & Temperature Relief Valve (PTR15/1000) ⚙️🔥
Manufactured by Australian Valve Group (AVG), this valve ensures safe, automatic discharge when pressure or temperature exceed safe operating limits — keeping your system efficient, reliable, and compliant with Australian Standards 🇦🇺


⚙️ Product Overview

The AVG PTR15/1000 is a high-quality brass combination valve that performs both pressure and temperature relief functions.
It’s designed for mains-pressure storage water heaters and automatically releases water when the internal tank temperature or pressure exceeds preset safety levels.

Essential for electric, gas, and solar hot water systems, this valve provides vital protection and peace of mind 💦


Key Features & Benefits


🧾 Technical Specifications

Specification Detail
Model PTR15/1000
Brand AVG
Inlet Size 15mm (½″ BSP male)
Outlet Size 15mm female BSP
Pressure Rating 1000 kPa
Temperature Rating 99°C
Body Material Brass
Spring Material Stainless Steel
Certification WaterMark AS1357.1
Application Hot Water Systems

🧩 Applications

✅ Electric storage water heaters
✅ Gas hot water systems
✅ Solar hot water systems
✅ Commercial water storage units

💡 Tip: A PTR valve is a legal requirement on all storage hot water systems in Australia — it prevents tank rupture and ensures user safety.


🧑🔧 Installation Tips

⚠️ Must be installed by a licensed plumber in accordance with AS/NZS 3500 and AS1357.1.

1️⃣ Isolate the water and power supply.
2️⃣ Remove the existing PTR valve if fitted.
3️⃣ Apply thread seal tape to the male inlet.
4️⃣ Fit the new AVG PTR15/1000 securely into the heater’s relief port.
5️⃣ Attach discharge pipe pointing downward to a safe drain.
6️⃣ Turn on the supply and test the valve using the easing lever ✅

📸 Pro Tip: Operate the lever every 6 months to prevent scale buildup and ensure proper function.


💬 Common Signs You Need a New PTR Valve

💧 Constant dripping or leaking from discharge pipe
⚙️ Valve not releasing during test
🔥 Water temperature too high
🚫 Corroded or seized lever

Replacing your valve restores safe pressure control and prevents costly damage to your hot water tank.


🌟 Why Choose AVG?

✅ Australian-made & WaterMark certified 🇦🇺
✅ Trusted by plumbers nationwide
✅ Brass and stainless steel construction for longevity
✅ Compact, easy-to-install design
✅ Fully compliant with Australian Standards

AVG valves are reliable, durable, and designed for Australian water conditions, ensuring consistent protection and peace of mind for years to come 💪


📦 What’s Included


🔍 SEO Keywords / Tags

AVG PTR15/1000, 15mm pressure temperature relief valve, ½ inch PTR valve, 1000kPa hot water valve, hot water system safety valve, AVG brass valve, WaterMark AS1357.1, Australian Valve Group PTR, HWS relief valve, AVG hot water parts Australia.

View product